椎体成形治疗后骨水泥在椎体内弥散的影响因素

吴强 莫世赞 包拥政 胡孔和 何小龙 朱文刚 席新华 钟学仁 徐锦明

中国组织工程研究Issue(43):6922-6928,7.
中国组织工程研究Issue(43):6922-6928,7.DOI:10.3969/j.issn.2095-4344.2014.43.006

椎体成形治疗后骨水泥在椎体内弥散的影响因素

Influencing factors for bone cement dispersion within the vertebral body after vertebroplasty

吴强 1莫世赞 1包拥政 1胡孔和 1何小龙 1朱文刚 1席新华 1钟学仁 1徐锦明1

作者信息

  • 1. 汕头大学医学院附属粤北人民医院骨科四区,广东省韶关市 512026
  • 折叠

摘要

Abstract

BACKGROUND:Percutaneous vertebroplasty and kyphoplasty are both effective in the treatment of osteoporotic vertebral compression fractures, but different in the distribution and dispersion of bone cement. <br> OBJECTIVE:To analyze the factors affecting the bone cement dispersion within the vertebral body in treatment of osteoporotic vertebral compression fracture with vertebroplasty or kyphoplasty. <br> METHODS:A total of 41 patients with osteoporotic vertebral compression fractures were included, and divided into three groups:group A (22 cases receiving high viscosity bone cement vertebroplasty treatment), group B (5 cases receiving high viscosity bone cement kyphoplasty), group C (14 cases receiving low viscosity bone cement vertebroplasty treatment). The groups A and C were divided into subgroups according to bone cement injection volume, time from fracture to operation, preoperative degree of vertebral compression. The distribution and dispersion of bone cement in the vertebra were reconstructed by the CT three-dimensional imaging and volume rendering analysis. <br> RESULTS AND CONCLUSION:In the three groups, after operation, relative dispersion area and relative dispersion volume in the vertebrae had no obvious difference, and the bone cement could al diffuse to upper and&nbsp;lower lamina cross the vertebral midline. There was no significant difference in bone cement diffusion coefficient among the three groups. In a certain range, the bone cement injection volume and bone cement dispersion volume was positively correlated. In groups A and C, bone cement diffusion coefficient decreased with the increasing of bone cement injection volume, time from fracture to operation, and the compression degree of the fractured vertebrae, but showed no significant correlation with bone cement viscosity.

关键词

生物材料/骨生物材料/骨质疏松椎体压缩性骨折/椎体成形/CT三维重建/骨水泥/弥散特征

分类

医药卫生

引用本文复制引用

吴强,莫世赞,包拥政,胡孔和,何小龙,朱文刚,席新华,钟学仁,徐锦明..椎体成形治疗后骨水泥在椎体内弥散的影响因素[J].中国组织工程研究,2014,(43):6922-6928,7.

基金项目

韶关市科技局重点攻关项目(2012CX/K105)Funding:the Tackle Key Project of Shaoguan Science and Technology Bureau, No.2012CX/K105 (2012CX/K105)

中国组织工程研究

OA北大核心CSTPCD

2095-4344

访问量0
|
下载量0
段落导航相关论文