| 注册
首页|期刊导航|移动通信|高压电力线在3MHz-30MHz电磁干扰下的建模分析研究

高压电力线在3MHz-30MHz电磁干扰下的建模分析研究

张宁 刘燕

移动通信Issue(10):66-70,5.
移动通信Issue(10):66-70,5.DOI:10.3969/j.issn.1006-1010.2015.10.013

高压电力线在3MHz-30MHz电磁干扰下的建模分析研究

Analysis and Research on 3MHz-30MHz Electromagnetic Interference Modeling of High Voltage Power Line

张宁 1刘燕1

作者信息

  • 1. 国家无线电监测中心乌鲁木齐监测站,新疆 乌鲁木齐 830000
  • 折叠

摘要

Abstract

In order to enhance quality and efficiency shortwave monitoring and avoid the influence of electromagnetic interference, active jamming mechanism of high voltage power line affecting shortwave monitoring was analyzed in this paper. According to the calculation principles of vertical dipole model radiation ifeld and corona ifeld of single high voltage power line, 3MHz—30MHz electromagnetic interference was modeled and analyzed. In addition, active interference benchmark level of high voltage power line was quantitatively calculated and compared with tested data. Results show that, in frequency range of 3MHz—30MHz, the strength of electromagnetic interference is different in the conditions of multiple and single high voltage power lines; but the change trend of electromagnetic interference in these two conditions is overall consistent with the change trend of tested data ifeld strength.

关键词

高压电力线/短波监测/有源干扰/起晕场

Key words

high voltage power line/shortwave monitoring/active jamming/corona ifeld