Abstract
Existing problems in the anti-surge valve and inlet guide vane, oxygen trans-fer valve and vent valve and switch valve of molecular sieve absorber of air separating plant and modification measures are introduced. Existing problems in the low-temperature and room temperature pneumatic valves and the inlet guide vane of nitrogen compressor and maintenance measures are also discussed.关键词
空分设备/阀门/入口导叶/卡阻/调节性能/压力Key words
air separating plant/valve/inlet guide vane/jamming/adjusting function/pressure分类
通用工业技术引用本文复制引用