Analysis on Application Conditions of Formula (B.3) and (B.4) in Appendix B of GB 150 .1-2011

吴全龙 1陈朝晖2

作者信息

  • 1. 上海华理安全装备有限公司,上海 201108
  • 2. 全国锅炉压力容器标准化技术委员会,北京100029
  • 折叠

摘要

Abstract

Comparative analysis between GB 150.1—2011 appendix B and API Std 521—2007 on the calculation of fire-relief capacity in the liquefied gas vessel was made.The approach on how to derivate the formula of heat flux in the API Std 521—2007 was given.It concludes that the formula (B.3) and ( B.4) in GB 150.1—2011 appendix B should be confined to the open pool fire.This conclusion can of-fer reference for the designer of pressure vessel and the maker of the standard.

关键词

安全泄放量/油池火/喷射火/敞开式火灾/吸热量

Key words

safety relief capacity/pool fire/jet fire/open fire/heat flux