原子能科学技术Issue(5):908-912,5.DOI:10.7538/yzk.2014.48.05.0908
铀生产工艺设备中滞留量测量的自吸收校正方法
Self-absorption Correction Method for Holdup Measurement in Uranium Produced Tank
何丽霞 1甘霖 1隋洪志 1陈立君2
作者信息
- 1. 中国原子能科学研究院 放射化学研究所,北京 102413
- 2. 中国核工业集团公司,北京 100086
- 折叠
摘要
Abstract
Achieving exactly quantitative holdup in uranium produced tank is a key point for nuclear material account and control .Due to the tank’ s particularity design and gamma ray remarkable self-absorption , conventional calibration methods can ’ t be adopted for self-absorption data analysis .The self-absorption correction method in the special case was researched , and also a two-dimensional model for self-absorption correction was established .It is available for these cases such as thickness of the material , matrix ingredients and geometric are incomprehensive . The validation of simulation sample shows that the two-dimensional model meets the requirement of holdup measure-ment in uranium produced tank .关键词
滞留量/核材料衡算/自吸收校正/自吸收二维校正模型Key words
holdup/nuclear material account/self-absorption correction/two-dimensional model for self-absorption correction分类
能源科技引用本文复制引用
何丽霞,甘霖,隋洪志,陈立君..铀生产工艺设备中滞留量测量的自吸收校正方法[J].原子能科学技术,2014,(5):908-912,5.