原子能科学技术Issue(10):1803-1806,4.DOI:10.7538/yzk.2014.48.10.1803
A P1000安全壳流动循环与热分层一维模型分析
One-dimensional Model Analysis of Flow Circulation and Thermal Stratification in AP 1000 Containment
摘要
Abstract
Passive containment cooling system is one of the important safety systems in AP1000 .The heat produced in the containment can be transferred to the atmosphere based on natural circulation both in the containment and in the air flow channel outside the containment .T he flow circulation and thermal stratification in the large volume of the containment have essential effect on the flow and heat transfer .In this paper ,one-dimensional thermal-hydraulic model was established based on stratification theory for the natural circulations in and outside the steel containment .The calculation efficiency was improved and the temperature distribution was obtained .By comparing with the result of the three-dimensional model ,the rationality of the one-dimensional model was veri-fied .The pressure and constituent distributions in the containment were also calculated .关键词
非能动安全壳/热分层/一维模型Key words
passive containment/thermal stratification/one-dimensional model分类
能源科技引用本文复制引用
玉宇,张鹤,单祖华,胡迎秋,王升飞,牛风雷,刘鑫,刚直..A P1000安全壳流动循环与热分层一维模型分析[J].原子能科学技术,2014,(10):1803-1806,4.基金项目
国家自然科学基金资助项目(51206042);中央高校基本科研业务经费资助项目 ()