原子能科学技术Issue(1):154-161,8.DOI:10.7538/yzk.2015.49.01.0154
HIRFL-CSR 外靶实验读出电子学预研系统
Prototype Readout Electronics System of External Experiment in HIRFL-CSR
摘要
Abstract
A prototype of the readout electronics system was designed for the external experiment in HIRFL‐CSR .This system is responsible for the readout of the TOF wall detector ,the neutron wall detector and the MWDC .The time measurement was based on leading edge discrimination ,while the TOT method was employed in charge meas‐urement ,and this made the time‐walk to be corrected . The electronics was designed based on the PXI standard in order to guarantee that this system has a high data transfer rate and a good flexibility . T he laboratory tests and preliminary commissioning tests with the detectors were conducted ,which indicate the system functions are good .关键词
兰州重离子加速器/外靶实验/时间测量/电荷测量/T O T/PXIKey words
HIRFL/external experiment/time measurement/charge measurement/T O T/PXI分类
能源科技引用本文复制引用
康龙飞,赵雷,李敏,周家稳,刘树彬,安琪..HIRFL-CSR 外靶实验读出电子学预研系统[J].原子能科学技术,2015,(1):154-161,8.基金项目
国家自然科学基金资助项目(11079003);中国科学院知识创新工程重要方向性项目资助 ()