Clinical trials of the new 3-dimensional reticular intrauterine device for reproductive women

邱毅 1王磊光 2于玲1

作者信息

  • 1. 国家卫生和计划生育委员会生育调控技术重点实验室,山东省计划生育科学技术研究所,济南250002
  • 2. 山东省优生技术重点实验室,山东省计划生育科学技术研究所,济南250002
  • 折叠

摘要

Abstract

This study aimed at exploring a new 3-dimensional reticular intrauterine device (3-DR-IUD) composed of nitinol and silicone rubber and observing the contraceptive efficacy and side effects of the device in reproductive women. The frame of the 3-DR-IUD was con-structed with silicone rubber and nitinol wire. The 3-DR-IUD was placed into uterus in an outpa-tient procedure. One hundred and fifty-two women were divided equally into the 3-DR-IUD group (n=76) and the 2-dimensional intrauterine device (2-D-IUD) group (n=76,control group). Patient follow-ups were performed in 1~12 months post-operation. The side effects of intrauterine device (IUD),such as abnormal leucorrhea,menstrual flow changes in uterine bleeding profusely and pain,etc,were investigated. The pregnancy rate,expulsion rate,re-moval rate of IUD for medical reasons and the continuation rate were evaluated. The ultrasound and pelvic X-ray were carried out to examine IUDs. The results showed that two groups with 76 cases of each successfully placed IUD and there were no severe pain during the operation. The incidence of lumbago/abdominal pain and the occurrence of leucorrhea and irregular vaginal bleeding in the 3-DR-IUD group (7.9 %,6/76) were significantly lower than that of the 2-D-IUD group (40.8 %,31/76) during the first 12 months for use of IUD (P<0.000 1). The preg-nancy rate,expulsion rate and take-off rate due to symptom were 0%,0%and 1.3%in 3-DR-IUD group,respectively,and 1 of 76 woman take-off 3-DR-IUD was due to allergy for silicon rubber. The continuation rate was 98.7%(75/76) in the 3-DR-IUD group,comparing with the 2-D-IUD group (86.8 %, 66/76) , the difference was significantly (P=0.009). Therefore , the 3-DR-IUD demonstrates long-term patient tolerability,satisfaction and efficacy as a contra-ceptive. The 3-DR-IUD appears to be a new,safe and effective devise of contraception.

关键词

3-DR-IUD/临床实验/副反应/避孕效果

Key words

3-DR-IUD/clinical trials/side effects/contraceptive efficacy

分类

医药卫生

引用本文复制引用

邱毅,王磊光,于玲..新型立体式网状宫内节育器初步临床观察[J].中国工程科学,2014,(5):39-46,8.

基金项目

山东省人口和计划生育科研计划项目 ()

中国工程科学

OA北大核心CSTPCD

1009-1742

访问量0
|
下载量0
段落导航相关论文