| 注册
首页|期刊导航|中国临床药理学杂志|血管回声跟踪技术检测2型糖尿病肾病患者颈动脉弹性的临床意义

血管回声跟踪技术检测2型糖尿病肾病患者颈动脉弹性的临床意义

周小爱 朱绥 朱长远 王筱璟 李庆

中国临床药理学杂志Issue(8):657-660,4.
中国临床药理学杂志Issue(8):657-660,4.DOI:10.13699/j.cnki.1001-6821.2015.08.022

血管回声跟踪技术检测2型糖尿病肾病患者颈动脉弹性的临床意义

E-tracking technique for the detection of artery elasticity function of patients with type 2 diabetes combined with nephropathy

周小爱 1朱绥 2朱长远 3王筱璟 1李庆1

作者信息

  • 1. 宁波市鄞州第二医院 内分泌科,浙江 宁波 315100
  • 2. 宁波市鄞州区姜山中心卫生院,浙江宁波 315100
  • 3. 金华市中医医院B超室,浙江金华 321000
  • 折叠

摘要

Abstract

Objective To detect artery elasticity function of patients with type 2 diabetes combined nephropathy by E -Tracking ( ET) tech-nique and to evaluate its clinical significance .Methods One hundred patients with type 2 diabetes were selected and divided into normal urine protein group (35 cases), minimal urine protein group (36 cases), and clinical urine protein group (29 cases) according to 24 h urinary albumin excretion rate , and 30 healthy volunteers were selected as normal control group.The data of blood vessel elastic modulus , including pressure -strain elastic modulus , stiffness parameters , arterial compliance , aug-ment index , and pulse wave conducting velocity of all objects were detec-ted by ET technique.Results The value of pressure -strain elastic modulus , stiffness parameters , augment index and pulse wave conducting velocity in diabetes group were higher than those in normal control group , and the value of arterial compliance in diabetes group was lower than that in normal control group (P<0.05).There were no statistical differences in parameters of pressure -strain elastic modulus , stiffness parameters , augment index and pulse wave conducting velocity between minimal urine protein group and normal urine protein group ( P>0.05 ) .The value of&nbsp;arterial compliance in minimal urine protein group was significantly lower than that in normal urine protein group and there was statistical significance (P<0.05).The value of pressure -strain elastic modulus, stiffness parameters, aug-ment index and pulse wave conducting velocity in clinical urine protein group were higher than those in normal urine protein group and minimal urine protein group , and the value of arterial compliance in clinical urine protein group was lower than that in normal urine protein and minimal urine protein group and there was statistical significance ( P<0.05 ) .Furthermore ,the results of multiple logistic regression analysis showed that urinary albumin excretion rate was positively related with stiffness parameters and pulse wave conducting velocity ( P<0.01 ).Conclusion Carotid artery elasti-city has changed in patients with type 2 diabetes combined early stage of nephropathy .Carotid artery elas-ticity detected by ET technique can reflect the process of microvascular disease and provide scientific basis for early pre -vention and cure .

关键词

2型糖尿病肾病/颈动脉弹性/血管回声跟踪(ET)技术

Key words

type 2 diabetes nephropathy/artery elasticity function/E-tracking ( ET) technique

分类

医药卫生

引用本文复制引用

周小爱,朱绥,朱长远,王筱璟,李庆..血管回声跟踪技术检测2型糖尿病肾病患者颈动脉弹性的临床意义[J].中国临床药理学杂志,2015,(8):657-660,4.

基金项目

浙江省卫生适宜技术成果转化基金资助项目 ()

中国临床药理学杂志

OA北大核心CSCDCSTPCD

1001-6821

访问量1
|
下载量0
段落导航相关论文