Objective:To evaluate the performance of paramagnetic particles chemiluminescence microparticle immunoassay ( CMIA) for detection of serum Vitamin B12 ( VitB12 ).Methods: Analysed CMIA system precision, accuracy, anti-interference, analytical measuring range( AMR) ,clinical reportable range ( CRR) and biological reference interval were evaluated,according to the clinical and laboratory standards institude ( CLSI) EP5-A2,EP15-A2,EP7-A2,EP6-A,C28-A3c guidelines.To assess the accuracy,we used the reference material SRM 1955 from national institute of standards and technology ( NIST ) and external quality assessment ( EQA) samples ( LN5-B and K-C) from CAP.Results:The precisions of within-run and between-run were less than standard of manu-facturer when the concentration of VitB12 was 108.84-874.43 pmol/L.The results of SRM1955 met the allowable range of the target val-ue.The results of EQA samples( K-C and LN5-B) also up to the CAP calibration and validation/linear evaluation error limits stipulated standards,and the results through linear verification when the concentration of VitB12 was 89-1 057 pmol/L.The 95% verification interval contains the specified value also.The relative deviation was less than external quality assessment standard from national center for clinical laboratory ( TEa:target value ±25%).Anti-interference evaluation showed without significant interferenc when TG ≤20 mmol/L,Bil ≤300 μmol/L VitC≤1.5 g/L to the VitB12 detection system ( CMIA).AMR validation showed determines the best fit equation was linear equation polynomial.There was the linear relationship when the concentration of VitB12 was 0-1 107 pmol/L.The upper limit of CRR was 110 700 pmol/L,the maximum dilution was 100 times.Biological reference interval validation showed that the overall level of VitB12 in this study reference individuals conform to the standard of manufacturer statement for the population,the overall level of VitB12 in female little higher than male,but no significant differences.Conclusion:Performance of CMIA for detection of serum VitB12 basically met needs of laboratory,which can provide reliable results of VitB12 for laboratory,provide information for the VitB12 status of population in the laboratory evaluation.

关键词

维生素B12/微粒子化学发光免疫法/微粒子化学发光免疫分析仪

Key words

Vitamin B12/Chemiluminescence microparticle immunoassay/Chemiluminescence microparticle immunity analyzer

分类

医药卫生

引用本文复制引用

安崇文,李海霞,孟群,胡建平,徐向东..顺磁性微粒子化学发光免疫分析法检测血清维生素B12的性能评价[J].中国免疫学杂志,2014,(11):1508-1513,6.

基金项目

本文为国家科技支撑计划基金资助项目(No.2012BAH24F01)。 ()

中国免疫学杂志

OA北大核心CSCDCSTPCD

1000-484X

访问量0
|
下载量0
段落导航相关论文