Abstract
OBJECTIVE:To study the adsorbability of plastic transfusion bottle and infusion set to diazepam. METHODS:With the reference of plastic-bottled 5% glucose injection,HPLC was used to determine the changes of mass concentration of diazepam adding into plastic-bottled 5% glucose injection at different time;disposable plastic infusion set was connected to simulate intrave-nous infusion and determine the changes of mass concentration of diazepam in the liquid effluent at different time. RESULTS:The mass concentration of diazepam in glass infusion bottles group was higher than in plastic transfusion bottles group. The adsorbabili-ties of solutions showed the strongest at the time of 15-20 min. The mass concentration of the effluent liquid from the glass bottle group was about 80% of the original concentration and plastic bottle group was about 67%. As the time went on,the adsorbability was gradually saturated at 60 min and the concentration rose again;the mass concentration of the effluent liquid from the glass bot-tle group returned to 95%of the original concentration at 80 min and the plastic bottle group was about 75%of the original concen-tration. CONCLUSIONS:Both plastic infusion bottle and infusion set have strong adsorbability to diazepam. It is suggested that the dosage of diazepam should be increased by 25% to 33% while plastic-bottled 5% glucose injection is used as solvent for intrave-nous drip.关键词
塑料输液瓶/一次性塑料输液器/地西泮/吸附性/高效液相色谱法Key words
Plastic infusion bottle/Disposable plastic infusion set/Diazepam/Adsorbability/HPLC分类
医药卫生引用本文复制引用
夏清荣,梁俊,曹银..塑料输液瓶和输液器对地西泮的吸附性考察[J].中国药房,2015,(18):2564-2566,3.