中国医学创新Issue(9):134-135,136,3.DOI:10.3969/j.issn.1674-4985.2015.09.045
超声技术在颈内静脉穿刺置管中的应用
Application of Ultrasonic Technique in Internal Jugular Vein Puncture Tube
摘要
Abstract
Objective:To observe the application of ultrasonic technique in internal jugular vein puncture tube. Method:75 cases of ASAⅠ-Ⅱpatient were selected randomly and divided into three groups(25 cases a group):conventional group(group I),group of B-ultrasound localization(groupⅡ),group of B-ultrasound guidance(groupⅢ). The time of puncture in the two groups,one-time successful puncture rates,puncture times and the complication rates were observed. Result:One-time successful puncture rates in groupⅢwas 92.0%,and the rates in groupⅡwas 84.0%. The rates in groupⅡandⅢwere significantly higher than 60.0%in convention group. And the time of puncture in groupⅡandⅢwere significantly less than group I. The comparison result had statistical significance(P<0.05). The complication rates in groupⅢwere 8.0%and 16.0%in groupⅡwhich were significantly less than 44.0%in group I. The comparison result had statistical significance(P<0.05). Conclusion:The ultrasonic technique in internal jugular vein puncture tube is a highly-effective and safe technique to greatly improve the success rate of puncture,shorten the puncture time and reduce the complications which is worthy for extending in clinic.关键词
超声/颈内静脉/穿刺置管/应用Key words
Ultrasound/Internal jugular vein/Puncture tube/Application引用本文复制引用
黄鑫,黎艳华,王月玲,黄翠玲,高启俊..超声技术在颈内静脉穿刺置管中的应用[J].中国医学创新,2015,(9):134-135,136,3.基金项目
江门市科技计划项目 ()