中国医学装备Issue(2):16-19,20,5.DOI:10.3969/J.ISSN.1672-8270.2015.02.005
数字X射线摄影系统量子探测效率检测方法研究
Study on test methods of detective quantum efficiency in DR system
摘要
Abstract
Objective: This paper introduces the test methods and significance of detective quantum efficiency (DQE). Methods:According to the IEC 62220-1 standard, test methods of DQE is analyzed, relationships between DQE and other important factors which might affect the digital X-ray image quality are analyzed. Results: Main factors including noise, contrast, MTF, patient’s dose are concluded. Conclusion:DQE combines some important factors together including image contrast, noise, and spatial resolution and input X-ray dose, which makes it as the most accurate method in evaluating digital X-ray image quality.关键词
数字X射线摄影系统/平板探测器/量子探测效率/医学图像Key words
DR system/Flat panel detector/Detective quantum efficiency/Medical image分类
医药卫生引用本文复制引用
赵庆军,徐桓,刘晓军,孙喜文..数字X射线摄影系统量子探测效率检测方法研究[J].中国医学装备,2015,(2):16-19,20,5.基金项目
全军医学科研“十二五”课题计划(BWS11J015)“卫生装备质量控制与技术保障关键技术研究” (BWS11J015)