| 注册
首页|期刊导航|浙江电力|燃煤发电机组脱硫塔浆液起泡问题分析及应对措施

燃煤发电机组脱硫塔浆液起泡问题分析及应对措施

毛文利 李辉 陈彪

浙江电力Issue(5):48-51,4.
浙江电力Issue(5):48-51,4.

燃煤发电机组脱硫塔浆液起泡问题分析及应对措施

Analysis and Countermeasures of Seriflux Foaming in Desulfuration Tower of Coal-fired Generating Units

毛文利 1李辉 1陈彪1

作者信息

  • 1. 国网浙江省电力公司电力科学研究院,杭州 310014
  • 折叠

摘要

Abstract

The seriflux foaming in desulfuration tower and its harm after coal-fired units desulfurization bypass canceled are analyzed. The paper investigates foaming mechanism of desulfurization seriflux. On the basis of analyzing the causes for foaming of desulfuration tower , this paper presents technical measures to solve seri-flux foaming and overflow problems in absorption tower , which solves foaming problem after coal-fired units cancel bypass gas flue.

关键词

湿法脱硫/浆液起泡/溢流/消泡剂

Key words

wet desulfurization/seriflux foaming/overflow/defoamer

分类

资源环境

引用本文复制引用

毛文利,李辉,陈彪..燃煤发电机组脱硫塔浆液起泡问题分析及应对措施[J].浙江电力,2014,(5):48-51,4.