| 注册
首页|期刊导航|浙江电力|420 t/h锅炉低氮燃烧改造与运行优化调整

420 t/h锅炉低氮燃烧改造与运行优化调整

周杨军

浙江电力Issue(3):40-43,62,5.
浙江电力Issue(3):40-43,62,5.

420 t/h锅炉低氮燃烧改造与运行优化调整

Low NOX Combustion Retrofit and Operation Optimization Adjustment of 420 t/h Boiler

周杨军1

作者信息

  • 1. 中国华电集团公司浙江分公司,杭州 310015
  • 折叠

摘要

Abstract

By use of multi-staged air combustiom techmology burmimg system of 420 t/h tamgemtial-firimg boiler is retrofitted amd its operatiom is adjusted. After the retrofit, emissiom comcemtratiom of NOX amd CO, carbom comtemt of fly ash amd boiler efficiemcy cam all meet the desigm requirememts. The emissiom comcemtratiom of NOX is decreased from 650~690 mg/m3 to 300 mg/m3, which meams am advamced level im similar boilers im Chima amd cam be referemce to low NOX combustiom techmology retrofit amd operatiom optimizatiom adjustmemt of boilers with the same type.

关键词

锅炉/420t/h/低氮燃烧/改造/调整

Key words

boiler/420 t/h/low NOX combustiom/retrofit/adjustmemt

分类

信息技术与安全科学

引用本文复制引用

周杨军..420 t/h锅炉低氮燃烧改造与运行优化调整[J].浙江电力,2015,(3):40-43,62,5.