For analyzing reasons of leakage current increase and local heating of the metal oxide arrester (MOA), this paper diagnoses the operating state of MOA by combining live testing record, power-off test da-ta, historical data and relevant regulations and determines that the MOA is in a state of serious defect. The uneven distribution of insulating strength, resistors aging of metal oxide at the bottom of the MOA and the de-crease of insulation resistance are found through disintegrating inspection and test.