浙江电力Issue(6):28-30,3.
某110 kV金属氧化物避雷器缺陷的检测与分析
Defects Detection and Analysis of a 110 kV MOA
林根德 1陈达 1朱海貌1
作者信息
- 1. 国网浙江省电力公司温州供电公司,浙江 温州 325000
- 折叠
摘要
Abstract
For analyzing reasons of leakage current increase and local heating of the metal oxide arrester (MOA), this paper diagnoses the operating state of MOA by combining live testing record, power-off test da-ta, historical data and relevant regulations and determines that the MOA is in a state of serious defect. The uneven distribution of insulating strength, resistors aging of metal oxide at the bottom of the MOA and the de-crease of insulation resistance are found through disintegrating inspection and test.关键词
金属氧化物避雷器/带电检测/泄漏电流/局部发热Key words
metal oxide arrester/live detection/leakage current/local heating分类
信息技术与安全科学引用本文复制引用
林根德,陈达,朱海貌..某110 kV金属氧化物避雷器缺陷的检测与分析[J].浙江电力,2015,(6):28-30,3.