制冷技术Issue(2):1-7,7.DOI:10.3969/j.issn.2095-4468.2015.02.101
基于单相R744喷射器系统的引射比计算模型及其实验验证
Mathematical Model and Experimental Validation for Mass Entrainment Ratio of Ejector System with Single Phase R744
熊杰 1王如竹 1EIKEVIK Trygve Magne2
作者信息
- 1. 上海交通大学制冷与低温工程研究所,上海200240
- 2. 挪威科技大学,特隆赫姆7491
- 折叠
摘要
Abstract
Based on the existing mathematical model of mass entrainment ratio, a hybrid model for single phase R744 ejector system was developed. Firstly, based on the fluid dynamics and heat transfer theory, a theoretical model of mass entrainment ratio was established, and then it was simplified by considering the fluid status at the ejector inlet and outlet. The obtained new mathematical model contains five unknown parameters, and the fitting method for the parameters is also given. The comparisons of the calculation and experimental results indicate that the new model has a higher accuracy.关键词
喷射器/引射比/计算模型/R744Key words
Ejector/Mass entrainment ratio/Mathematical model/R744引用本文复制引用