| 注册
首页|期刊导航|发电与空调|300MW机组给水泵汽轮机无法挂闸原因分析及处理

300MW机组给水泵汽轮机无法挂闸原因分析及处理

顾莉莉

发电与空调Issue(2):28-31,4.
发电与空调Issue(2):28-31,4.DOI:10.3969/J.ISSN.2095-3429.2015.02.008

300MW机组给水泵汽轮机无法挂闸原因分析及处理

Cause Analysis of Feedwater Pump Turbine of 300MW Unit Can’t Latching and Treatment

顾莉莉1

作者信息

  • 1. 浙江浙能绍兴滨海热电有限责任公司,浙江 绍兴 312073
  • 折叠

摘要

Abstract

Zhejiang zheneng Shaoxing coastal cogeneration Co. Ltd.has two sets of the steam driven feedwater pump for 300MW unit to water supply now. Steam driven feedwater pump operation is normal or not determines the safety and eco-nomic operation of the unit,so the reliability of the feedwater pump turbine is very important. Take one feedwater pump tur-bine of 300MW unit as an example,introducing the feedwater pump turbine can’t latching which leads to the unnormal use of water supply when in its beginning process. Through careful investigation to find out the cause of the fault, and restore the normal operation of the feedwater pump.

关键词

300MW机组/给水泵汽轮机/挂闸/分析处理

Key words

300MW unit/feedwater pump turbine/latching/analysis and processing