摘要

Abstract

The heat transfer between vertically buried pipe exchanger and soil surrounding is numerically simulated by business modeling software GAMBIT and FLURNT. Differing from the previous model with pure heat conduction,in this paper, the 3-D heat transfer model of buried pipe exchanger is established based on the theory of saturated porous media and groundwater flow ,to research the influence of groundwater seepage on the heat ex-change between vertically buried pipe and soil surrounding. The influence of groundwater seepage on the soil sur-rounding is studied mainly through the heat seepage coupled model of three-dimensional single U-shaped pipe which is vertically buried underground.

关键词

垂直地埋管换热器/地下水渗流/数值模拟

Key words

the U-vertical underground heat exchanger/groundwater seepage/numerical simulation