交流发光二极管(AC-LED)结温的测试方法OACSTPCD
Methodology of Junction Temperature Characterization of Alternating Current Light-Emitting Diodes
目前对交流发光二极管( AC-LED)的结温测试少有研究。将一种新的电学测试方法---阈值电压法应用到AC-LED结温测试当中,并与传统的峰值波长法进行对比。两种测试方法的结温测试结果相差在4℃之内,有较好的一致性。经过分析,当参考阈值电流为1mA时,阈值电压法的测试误差为±2.5℃,峰值波长法的测试误差为±6℃。阈值电压法测试结果更为精确,应用范围更广,更适用于工业测试。
At present , the measurement techniques of the junction temperatures of light emitting diodes ( LEDs) are developed for AC-LED.In the present work , a novel approach of threshold voltage method is proposed for junction temperature characterization of AC-LEDs.The new method was tested , and results of which were compared with the traditional peak wavelength method , showing a good agreement within 4℃. Further analysis suggested that the error of the threshold…查看全部>>
徐阁;于德鲁;邹兵;许键
上海理工大学教育部光学仪器与系统工程研究中心,上海 200093上海理工大学教育部光学仪器与系统工程研究中心,上海 200093上海理工大学教育部光学仪器与系统工程研究中心,上海 200093上海理工大学教育部光学仪器与系统工程研究中心,上海 200093
信息技术与安全科学
AC-LED结温测试方法峰值波长法阈值电压法
AC-LEDjunction temperaturemeasuring methodspeak wavelength methodthreshold voltage method
《照明工程学报》 2014 (3)
38-41,4
国家自然科学基金资助项目(项目编号610728007)