电机与控制应用Issue(8):58-60,3.
大容量高压电动机的起动
Starting Scheme for Large Capacity Medium-Voltage Motor
黄燕飞 1付薇 1齐茜茜 1夏子路1
作者信息
- 1. 中国石油集团工程设计有限责任公司华北分公司,河北 任丘 062552
- 折叠
摘要
Abstract
Three methods of soft starting, namely water resistance soft starter, solid-state soft starter and variable frequency device( VFD) soft starter were introduced. The advantages and disadvantages of the above three kinds of soft starting scheme for large capacity MV motor were analyzed, and especially the application of variable frequency soft starter for low power capacity system that starter's capacity is smaller than MV motor rating, in which VFD is not required in productive process.关键词
高压电动机/软起动/变频Key words
medium-voltage motor/soft starting/variable frequency分类
信息技术与安全科学引用本文复制引用
黄燕飞,付薇,齐茜茜,夏子路..大容量高压电动机的起动[J].电机与控制应用,2014,(8):58-60,3.