电器与能效管理技术Issue(14):17-21,27,6.
直流接触器断电不释放问题分析与研究
Analysis and Research on the DC Contactor Release Failure
刘艳妮 1周柳 2施金武2
作者信息
- 1. 海军驻上海711所军事代表室,上海 201108
- 2. 上海电器科学研究所 集团 有限公司,上海 200063
- 折叠
摘要
Abstract
The problem of DC contactor release failure after circuit open was studied .And the analysis was focused on two latent impact factors , namely , the increased magnetic force created by residual magnetism accumulation in the core and the adhesion force due to the paint melting under high temperature on the contact surface of the both poles .The effects of residual magnetic force and paint adhesion force on the contactor were described in details ,and via calculation and test ,the paint adhesion force proves to be the main effect ,and also the corresponding measures for improvement were proposed .关键词
直流接触器/断电不释放/剩磁吸力/漆膜黏结力Key words
DC contactor/release failure/residual magnetism force/paint adhesion force分类
信息技术与安全科学引用本文复制引用
刘艳妮,周柳,施金武..直流接触器断电不释放问题分析与研究[J].电器与能效管理技术,2015,(14):17-21,27,6.