电力系统保护与控制2015,Vol.43Issue(14):100-105,6.
基于频率-功率因数角组合判据的新型孤岛检测法
A new anti-islanding detecting method based on combined criterion of frequency and power-factor angle
王小立 1温靖华 1袁飞 2王燕萍2
作者信息
- 1. 国网宁夏电力公司,宁夏 银川750001
- 2. 华北电力大学,北京102206
- 折叠
摘要
Abstract
In order to solve the problem that the traditional methods are unable to ensure both power quality and the efficiency of detection, a new anti-islanding detection method is proposed based on the analysis of the relationship between the frequency and power-factor angle when islanding happens. The new method combines the varieties of frequency and the power-factor angle when islanding happens, which improves the sensibility of the criterion and enhances the reliability by delaying. Simulation proves that compared to the traditional method, the new method could detect islanding efficiently without affecting the power quality when the DG system is connected to the grid.关键词
孤岛检测/频率/功率因数角/组合判据/检测效率/电能质量Key words
islanding detection/frequency/power-factor angle/combination criterion/detection efficiency/power quality分类
信息技术与安全科学引用本文复制引用