| 注册
首页|期刊导航|中国组织工程研究|氨甲环酸用于全膝关节置换降低失血量的有效性及安全性

氨甲环酸用于全膝关节置换降低失血量的有效性及安全性

曹万军 朱绍灵 刘显东 唐承杰 郑金文 陈星宇 刘颖 肖鹏

中国组织工程研究Issue(31):4944-4948,5.
中国组织工程研究Issue(31):4944-4948,5.DOI:10.3969/j.issn.2095-4344.2015.31.005

氨甲环酸用于全膝关节置换降低失血量的有效性及安全性

Tranexamic acid reduces blood loss in total knee arthroplasty:effectiveness and safety

曹万军 1朱绍灵 1刘显东 1唐承杰 1郑金文 1陈星宇 1刘颖 1肖鹏1

作者信息

  • 1. 四川省骨科医院下肢科,四川省成都市 610041
  • 折叠

摘要

Abstract

BACKGROUND:Tranexamic acid is a synthetic anti-fibrinolytic drug, and can effectively control blood loss after total knee arthroplasty through vein. OBJECTIVE:To evaluate the effectiveness and safety of tranexamic acid in reducing blood loss after primary unilateral total knee arthroplasty. METHODS:From 2014 to 2015, 100 patients from the Department of Lower Limb, Sichuan Orthopaedic Hospital underwent primary unilateral total knee arthroplasty, and randomly divided into test group which used tranexamic acid and control group which used tranexamic acid, with 50 cases in each group. 1 g tranexamic acid was infused into the vein at 10 minutes before total knee arthroplasty in the test group, but tranexamic acid was not given in the control group. RESULTS AND CONCLUSION:The amount of total blood loss, postoperative wound drainage in 24 hours, and the amount of blood transfusion were significantly less in the test group than in the control group (P < 0.05). No significant differences in intraoperative blood loss and the number of patients receiving blood transfusion were found between the test and control groups. No significant difference in preoperative hemoglobin levels was detected before surgery, but hemoglobin levels were decreased after surgery between the two groups. Postoperative hemoglobin levels were apparently higher in the test group than in the control group after surgery. At 24 hours after surgery, no significant difference in coagulation was detectable between the two groups. At 6 days, double lower limb vein color Doppler ultrasound examination did not reveal deep vein thrombosis in both groups. These findings verify that treatment with tranexamic acid in the vein before primary unilateral total knee arthroplasty can evidently diminish the amount of perioperative blood loss and blood transfusion, reduce the risk&nbsp;and cost of blood transfusion, which is good for rehabilitation and does not increase the risk of deep vein thrombosis.

关键词

植入物/人工假体/氨甲环酸/全膝关节置换/失血量/深静脉血栓/输血

Key words

Tranexamic Acid/Arthroplasty, Replacement, Knee/Venous Thrombosis/Blood Transfusion

分类

医药卫生

引用本文复制引用

曹万军,朱绍灵,刘显东,唐承杰,郑金文,陈星宇,刘颖,肖鹏..氨甲环酸用于全膝关节置换降低失血量的有效性及安全性[J].中国组织工程研究,2015,(31):4944-4948,5.

中国组织工程研究

OA北大核心CSTPCD

2095-4344

访问量0
|
下载量0
段落导航相关论文