红水河2015,Vol.34Issue(4):40-44,5.
大化水电厂水导轴承瓦温偏高分析处理与预防
Analysis, Treatment and Prevention of Over Temperature of Turbine Guide Bearing Shoe in Dahua Hydropower Station
谭茂业1
作者信息
- 1. 广西桂冠电力股份有限公司大化水力发电总厂,广西 大化 530800
- 折叠
摘要
Abstract
The temperature of turbine guide bearing shoe keeps on high after the maintenance of No.1~No.4 units of Dahua hydropower station, which is not conductive to the long-term safe and stable operation of units. The station gives a solution for solving this problem through analyzing the structure of the turbine guide bearing and investigating the possible reasons of over-temperature of the guide bearing shoe. In addition, a preventive measure is proposed based on the obtained reason of over-temperature, and it receives the expected result.关键词
水导轴承/轴瓦温度/大化水电厂Key words
guide bearing shoe/temperature of turbine/Dahua hydropower station分类
建筑与水利引用本文复制引用
谭茂业..大化水电厂水导轴承瓦温偏高分析处理与预防[J].红水河,2015,34(4):40-44,5.