Abstract

There is serious cavitation erosion of the runner chamber of bulb tubular turbine in Bailongtan hydropower station after long time operation. The paper analyzes the causes of the cavitation erosion and introduces the repairing measures, technologies and the repaired effects after the chamber was returned to the factory, including the adjust-ments of roundness, levelness and centrality of the chamber, the laying-off and welding of anti-cavitation stainless steel plate and the preparation of turning program etc.

关键词

灯泡贯流式水轮机/转轮室/空蚀/百龙滩水电厂

Key words

bulb tubular turbine/runner chamber/cavitation/Bailongtan hydropower station