摘要
Abstract
A clear distinction to measure the harmonic contribution of the multiple nonlinear loads on point of common coupling of the power grid is important to achieve the division of responsibilities of the multi harmonic sources.This paper firstly uses the fluctuation method to transfer single phase uncontrolled rectifier circuit to Norton equivalent mod-el, and demonstrates the validity of the Norton equivalent model by comparing the value of harmonic current source and single-phase controlled rectifier circuit.Values of them are approximately equal.Then it sets up a circuit contains three harmonic sources and draws the Norton equivalent model of it.Finally, this paper calculates values of each har-monic voltage of every nonlinear load by using the equivalent impedance and uses voltage harmonic responsibility index factor dividing the responsibility of multi harmonic sources.This method is simple and effective, and it is also condu-cive to the practical application of distribution network with multi harmonic sources responsibility division.关键词
多谐波源/波动量法/诺顿等效模型Key words
multiple harmonic sources/fluctuation method/Norton equivalent model分类
信息技术与安全科学引用本文复制引用
刘晓璇,李建文,李永刚,郭亚成,刘胜军,王向东..基于诺顿等效电路的多谐波源责任划分研究[J].电测与仪表,2015,(17):79-83,5.