| 注册
首页|期刊导航|南华大学学报(自然科学版)|水中痕量镉的曙红Y-中性红能量转移荧光猝灭法测定

水中痕量镉的曙红Y-中性红能量转移荧光猝灭法测定

肖锡林 薛金花 廖力夫 肖明春 杜可杰 何博 邓昌爱

南华大学学报(自然科学版)Issue(1):91-96,6.
南华大学学报(自然科学版)Issue(1):91-96,6.

水中痕量镉的曙红Y-中性红能量转移荧光猝灭法测定

Determination of Trace Cadmium in Water with Eosine Y-Neutral Red by Energy Transfer Fluorescence Quenching Method

肖锡林 1薛金花 2廖力夫 1肖明春 2杜可杰 1何博 1邓昌爱1

作者信息

  • 1. 南华大学 化学化工学院,湖南 衡阳421001
  • 2. 南华大学 公共卫生学院,湖南 衡阳421001
  • 折叠

摘要

Abstract

In the Britton-Robinson buffer solution of pH7. 9,the system intensity was obvi-ously decreased due to the interaction between the Eosine Y-Neutral red complex and cad-mium ion,and the decreased fluorescence intensity was proportional to the concentration of cadmium ion. Based on this phenomenon,a novel energy transfer fluorescence quenching method for the determination of trace cadmium with EosineY-Neutral red was proposed.And this paper optimized experiment conditions. Under the optimal experimental conditions,there was a linear relationship between the decreased fluorescence intensity and the concentration of the cadmium at 535 nm in the range of 1. 6×10 -8 ~3. 2×10 -6 mol/ L, The linear regression equation was ∆F =936. 60 -2425. 2c(×10 -6mol/ L) with a correlation coefficient 0. 998,the detection limit was 4. 7×10 -9 mol/ L. The relative standard deviation was 0. 45% (n =6),and the average recovery was 90. 75%. The proposed method is simple,sensitive and selective,and has been used successfully in the determination of trace cadmium in water samples,which results were in good agreement with those gained by graphite furnace atomic absorption spectrometry (GFAAS) method.

关键词

曙红Y/中性红/镉离子/能量转移荧光猝灭法

Key words

Eosine Y/Neutral red/Cadmium(II)/energy transfer fluorescence quenching method

分类

化学化工

引用本文复制引用

肖锡林,薛金花,廖力夫,肖明春,杜可杰,何博,邓昌爱..水中痕量镉的曙红Y-中性红能量转移荧光猝灭法测定[J].南华大学学报(自然科学版),2014,(1):91-96,6.

基金项目

国家自然科学基金资助项目(31200140) (31200140)

南华大学学报(自然科学版)

1673-0062

访问量0
|
下载量0
段落导航相关论文