物理学报Issue(13):1-6,6.DOI:10.7498/aps.63.136001
X射线衍射仪固有角度刻度误差对点阵参数计算精确度影响的研究
Study on the effect of X-ray diffractometer inherent angle scale error on the precision of lattice parameter calculation
徐晓明 1苗伟 1陶琨1
作者信息
- 1. 清华大学材料科学与工程研究院中心实验室北京 100084
- 折叠
摘要
Abstract
This paper studies the effect of measuring angle error in X-ray powder diffractometer, which is caused by diffractome-ter inherent angle scale error resulting from mechanical manufacture, on the precision of calculated lattice parameter. It represents the theoretical limit of the consistency of the lattice parameters obtained by different diffractometers and laboratories. We use the calculated polysilicon diffraction patterns with random angle error to simulate the results mea-sured by many sets of diffractometers of some manufacturing precision, then calculate and analyze the lattice parameters by three methods.关键词
X射线衍射仪/固有角度刻度误差/点阵参数/精确度Key words
X-ray diffractometer/inherent scale error/lattice parameter/precision引用本文复制引用
徐晓明,苗伟,陶琨..X射线衍射仪固有角度刻度误差对点阵参数计算精确度影响的研究[J].物理学报,2014,(13):1-6,6.