中国药业Issue(16):91-92,93,3.
注射液用卤化丁基橡胶塞pH变化值测量不确定度的评定
Evaluation on Uncertainty Measurement of pH Variation in Halogenations Butyl Rubber Plug for Injection
聂蕾1
作者信息
- 1. 云南省医疗器械检验所,云南 昆明 650034
- 折叠
摘要
Abstract
Objective To analyze tbe balogenations butyl rubber plug for injection in accordance witb tbe YBB00042005 stan-dard. Methods Applying tbe JJF 1059 ″Evaluation and Expression of Uncertainty in Measurement″,tbe matbematical models were devel-oped for uncertainty evaluation for determination,tbe source of uncertainty was analyzed,and tbe evaluation metbod of uncertainty mea-surement of tbe pH variation in balogenations butyl rubber plug was establisbed. Results Tbe uncertainty report was:U=0. 20 ± 0. 04, k=2. Conclusion Tbis evaluation metbod bas a bigb practical value.关键词
丁基胶塞/pH变化值/测量不确定度Key words
balogenations butyl rubber for injection/pH variation/uncertainty measurement分类
医药卫生引用本文复制引用
聂蕾..注射液用卤化丁基橡胶塞pH变化值测量不确定度的评定[J].中国药业,2015,(16):91-92,93,3.