电力科技与环保Issue(5):57-59,3.
重量法测定燃煤电厂烟气中细颗粒物
Determination of PM2.5 in coal-fired power plant flue gas by weight method
易玉萍 1段玖祥 1周道斌 1张文杰 1姚杰 1赵洋1
作者信息
- 1. 国电环境保护研究院,江苏南京 210023
- 折叠
摘要
Abstract
The PM2.5(Particulate Matter 2.5) in flue gas of coal-fired power plant bring great damage to the en-vironment and human health.So the PM2.5 environmental monitoring is very important.The test principle and sampling method of PM2.5 were described.Also the error analysis of test results was discussed.The study re-sults indicated that the relative errors of this test method were between ±20%.关键词
燃煤电厂/细颗粒物(PM2.5)/测定方法/相对误差Key words
coal-fired power plant/particulate Matter 2.5(PM2.5)/test method/relative error分类
环境科学引用本文复制引用
易玉萍,段玖祥,周道斌,张文杰,姚杰,赵洋..重量法测定燃煤电厂烟气中细颗粒物[J].电力科技与环保,2015,(5):57-59,3.