电力科技与环保Issue(6):36-38,3.
燃煤机组SCR装置运行现状调查及存在问题分析
Survey on operation condition and in existing problems of SCR facilities in coal-fired units
尤良洲1
作者信息
- 1. 华电电力科学研究院,浙江 杭州 310030
- 折叠
摘要
Abstract
It surveyed the operation condition of SCR facilities in coal-fired units which has been running. The results show that under design conditions, the denitrification efficiency and concentration of nitrogen oxides of outlet can satisfied the requirement of guarantee value,but ammonia consumption and ammonia escape can not be ensured. It is harmful to safety of boiler operation in the long-time running.关键词
燃煤机组/烟气脱硝/SCR/运行现状Key words