电力勘测设计Issue(2):40-42,64,4.
直接空冷凝汽器传热系数与设计冷却裕量选择
Selection of Heat Transfer Coefficient and Cooling Allowance about Direct Air-cooled Condenser
顾国新1
作者信息
- 1. 安中国际工程技术北京有限公司,北京 100027
- 折叠
摘要
Abstract
In our country Direct air-cooling units have been widely used , but the most direct air-cooling unit has been put into operation can’t reach the designed value of unit full back pressure because of air-cooled condenser cooling capacity is not enough ,The author thinks that the condenser heat transfer coefficient and the design of cooling allowance choose not accurate is the main cause of the problem. Through the experimental study and a large number of engineering research analysis, proposed the choice method of these two key parameters, providing reference for the related engineering and technical personnel.关键词
空冷凝汽器/传热系数/设计冷却裕量/选择Key words
air-cooled condenser/heat transfer coefficient/design of cooling allowance/selection分类
信息技术与安全科学引用本文复制引用
顾国新..直接空冷凝汽器传热系数与设计冷却裕量选择[J].电力勘测设计,2013,(2):40-42,64,4.