电力系统自动化Issue(22):53-58,6.DOI:10.7500/AEPS20150205004
暂态稳定极限耦合的多个输电断面极限功率协调计算
Coordinated Limit Power Calculation of Multi-sections with Transient Stability Limit Coupling
摘要
Abstract
In order to quantitatively assess the interaction between transmission levels and implement automatic calculation of limit power of multi-sections simultaneously,a coordinated limit power calculating method of multi-sections coupled with transient stability limit is proposed.The coupling mechanism is analyzed first,and a coordinated model for the dominant limit power of multi-sections to reach critical stability at the same time is developed.Then a quantitative method for analyzing the influence of simultaneous variation of multi-section transmission power on stability margin is proposed.An iterative algorithm based on the mathematical programming method for solving power increase step size is designed,which can be used for offline or online analysis and real-time monitoring of transmission limit power of multi-sections.The validity of this method is verified by an example of an IEEE 10-unit 39-bus system.关键词
输电断面/多断面/极限功率/暂态稳定/交互影响Key words
power transmission section/multi-sections/limit power/transient stability/interactive influence引用本文复制引用
方勇杰,崔晓丹,王胜明,黄智达..暂态稳定极限耦合的多个输电断面极限功率协调计算[J].电力系统自动化,2015,(22):53-58,6.基金项目
国家电网公司大电网重大专项资助项目(SGCC-MPLG003-2012) (SGCC-MPLG003-2012)
国家电网公司科技项目“基于稳定性量化分析的大电网多断面暂态稳定交互影响及协调控制技术研究” ()