| 注册
首页|期刊导航|广东电力|电动钻机燃气孤岛电站并联储能系统荷电状态误差抑制

电动钻机燃气孤岛电站并联储能系统荷电状态误差抑制

李循迹 龙平 宋海涛 李永国 段建东 王炜信

广东电力Issue(9):12-17,6.
广东电力Issue(9):12-17,6.DOI:10.3969/j.issn.1007-290X.2015.09.003

电动钻机燃气孤岛电站并联储能系统荷电状态误差抑制

Error Suppression on State of Charge for Paralleled Storage System in Gas Island Power Station for Electric Drill Machine

李循迹 1龙平 1宋海涛 1李永国 1段建东 2王炜信2

作者信息

  • 1. 中石油塔里木油田分公司,新疆维吾尔自治区 库尔勒 841000
  • 2. 哈尔滨工业大学 电气工程学院,黑龙江 哈尔滨 150001
  • 折叠

摘要

Abstract

Battery energy storage system based on droop control strategy is widely used in island power station to keep stable operation of the system.Considering factors such as random,excursion of battery characteristic curve and output disturbance of running points of battery storage equipments,there must be differences of state of charge (SoC)of paralleled battery en-ergy storage system in discharge process.Therefore,a kind of droop control strategy for SoC error suppression was proposed to remove SoC errors among different storage equipments in running process of paralleled storage equipments.Damages to stable operation of island power grid caused from SoC errors of paralleled battery energy storage system were analyzed under the condition of traditional droop control.Then,SoC was introduced into active droop factor to decease SoC errors of stor-age equipments with curve of e index and reduce impact on the system in process of error convergence.In addition,charac-teristic of differential equation of first order was combined to adjust accelerated factor in control strategy and speed up sup-pression on SoC errors among paralleled battery energy storage system.Simulation results verified veracity of this theory and effectiveness of this scheme.

关键词

电动钻机/燃气孤岛电站/并联储能系统/SoC 误差抑制/动态均衡

Key words

electric drill machine/gas island power station/paralleled storage system/error suppression on state of charge/dynamic balance

分类

信息技术与安全科学

引用本文复制引用

李循迹,龙平,宋海涛,李永国,段建东,王炜信..电动钻机燃气孤岛电站并联储能系统荷电状态误差抑制[J].广东电力,2015,(9):12-17,6.