Abstract

This paper studies load carrying capability,security and economy of the boiler and coal pulverizing system after 600 MW subcritical unit co-firing with fault coal of high moisture andlowcalorific value.Results indicate that blending combus-tion with fault coal of high moisture and low calorific value may reduce drying capacity of the pulverizer and affect load car-rying capability and load variation rate of the boiler,so it is ought to reduce mixing proportion of fault coal when the boiler running with high load.Secondly,acid dew point of fuel gas obviously increases when co-firing with fault coal of high mois-ture and high sulfur content and low temperature corrosion aggravates as well.For fault coal easy to coking,it is able to ob-viously relieve coking by means of furnace mixing for co-firing with coal not easy to coking.Influence on the boiler efficien-cy is big by excessive air and air distribution mode while inverted-triangle air distribution mode is good for reducing heat loss of blending combustion with fault coal and producing NOx .In addition,blending combustion with fault coal may reduce boiler efficiency but entire economic benefit of the unit may increase.

关键词

600 MW 机组/劣质煤/掺烧/经济性/安全性/配风/低温腐蚀

Key words

600 MW unit/fault coal/blending combustion/economy/security/air distribution/low temperature corrosion

分类

能源科技

引用本文复制引用

林德平..600 MW 亚临界机组劣质煤掺烧试验研究[J].广东电力,2015,(9):37-42,91,7.

广东电力

OACSTPCD

1007-290X

访问量0
|
下载量0
段落导航相关论文