化工进展Issue(6):1278-1282,5.DOI:10.3969/j.issn.1000-6613.2013.06.013
亚临界燃煤电厂的用能分析
Energy analysis of subcritical coal-fired power plant
张彩珠 1王春燕 1陈珊 1魏顺安1
作者信息
- 1. 重庆大学化学化工学院,重庆 400044
- 折叠
摘要
Abstract
Systematic analysis of its energy consumption is important in energy conservation and emission reduction in the coal-fired power plants. This paper analyzed the energy consumption in a typical power plant and a specific power plant in southwest China. Aspen Plus software and energy analysis methods were used in the simulation and calculation of energy consumption. The results revealed that the largest energy consumption of the system occurs in the boiler,in which most energy was consumed in coal combustion. A great amount of energy is lost in the heat exchanging process on the surfaces in the boiler. The energy efficiency in the subcritical coal-fired power plant in southwest China is about 6 percent lower.关键词
燃煤电厂/Aspen Plus/有效能分析Key words
coal-fired power plant/Aspen Plus/energy analysis分类
能源科技引用本文复制引用
张彩珠,王春燕,陈珊,魏顺安..亚临界燃煤电厂的用能分析[J].化工进展,2013,(6):1278-1282,5.