辽宁工程技术大学学报(自然科学版)Issue(7):916-919,4.DOI:10.3969/j.issn.1008-0562.2013.07.011
矿井水反渗透处理系统设计要素
Key design factors of reverse osmosis system for mine drainage water treatment
摘要
Abstract
In order to optimize the system design of reverse osmoses (RO) for a mine drainage water treatment engineering as a case, this paper discusses the key design factors involving design water temperature, design recovery rate, numbers of RO membrane elements and arrangement types, by adopting the method combined analysis investigation with engineering practices. According to the water quality characteristics and the process requirements, the design water temperature of 25℃ is presented by calculation and comparison, and the checked condition is given as well. The design recovery rate of 60% and the limited recovery rate of 67% are determined by analyzing the main scaling components. Adopting the membrane element numbers of 144 and the configuration of one pass and two stages are considered by analyzing the effects on the water system caused by different membrane components and arrangement types. The engineering operation practice shows that the designed and operated RO system adopted the method reduces the scaling risks of RO membranes, has the benefits of stable operation for a long time, and has some guiding significance for designing and running the RO systems to treat mine drainage water.关键词
矿井水/深度处理/反渗透/回收率/化学清洗/膜元件/水温/结垢Key words
mine drainage water/advanced treatment/RO/recovery rate/chemical cleaning/membrane element/water temperature/scaling分类
矿业与冶金引用本文复制引用
毛维东,周如禄..矿井水反渗透处理系统设计要素[J].辽宁工程技术大学学报(自然科学版),2013,(7):916-919,4.基金项目
科技部技术开发研究专项资金资助项目 ()