宁夏电力Issue(3):46-49,4.DOI:10.3969/j.issn.1672-3643.2013.02.012
330 MW火电机组一次调频分析与优化
Analysis and optimization of primary frequency modulation of 300 MW coal-fired power generation units
王瑞 1张军 2李昱2
作者信息
- 1. 宁夏电力公司能源科技有限公司,宁夏 银川 750011
- 2. 国电石嘴山发电有限公司,宁夏 石嘴山 753202
- 折叠
摘要
Abstract
Aiming at the problems of primary frequency modulation responsed slowly, and larger de-viation between the frequency modulation amplitude and setting value in Shizuishan Power Genera-tion Co., Ltd., analyzes the reasons of problems occurred, puts forward optimization schemes. The anal-ysis result shows that there is stagnant tache in primary frequency modulation of digital electronic hy-draulic control system to influence badly the rate and amplitude value of frequency modulation. After the parameter optimization, the functions of primary frequency modulation basically meet the require-ments of power grid.关键词
一次调频/优化/火电机组/数字式电液控制系统Key words
primary frequency modulation/optimization/coal-fired power generation units/digital electronic hydraulic control system分类
信息技术与安全科学引用本文复制引用
王瑞,张军,李昱..330 MW火电机组一次调频分析与优化[J].宁夏电力,2013,(3):46-49,4.