| 注册
首页|期刊导航|物联网技术|一种新型高压信号引出装置的可靠性设计

一种新型高压信号引出装置的可靠性设计

张念东 贺伟

物联网技术Issue(8):56-58,3.
物联网技术Issue(8):56-58,3.

一种新型高压信号引出装置的可靠性设计

Reliability design of a new device for high-pressure chamber signal output

张念东 1贺伟1

作者信息

  • 1. 中国飞机强度研究所二十四室,陕西 西安 710065
  • 折叠

摘要

Abstract

The reliability of current device for high-pressure chamber signal output is poor, for its weak tightness and unsatisfactory components interchange. To enhancing the reliability, a new device for high-pressure chamber signal output is designed, and the reliability of sealing plug is tested. A series of reliability tests are conducted on the newly designed device for high-pressure chamber signal output, including high-pressure tightness test and electricity insulation performance test. The test results show that the new design can effectively solve the problem of poor tightness and improve the reliability of the product.

关键词

压力釜/成品率/密封塞/可靠性

Key words

pressure vessel/ifnished products rate/sealing plug/reliability