| 注册
首页|期刊导航|现代电子技术|基于MSP430F147的时差法超声波流量测量系统的研究

基于MSP430F147的时差法超声波流量测量系统的研究

李虹 田茸 胡钢墩

现代电子技术Issue(23):98-101,105,5.
现代电子技术Issue(23):98-101,105,5.DOI:10.16652/j.issn.1004-373x.2015.23.026

基于MSP430F147的时差法超声波流量测量系统的研究

Research on MSP430F147-based ultrasonic flow measurement system applied with time-difference method

李虹 1田茸 1胡钢墩1

作者信息

  • 1. 宁夏大学 物理电气信息学院,宁夏 银川 750021
  • 折叠

摘要

Abstract

In combination with the principle of ultrasonic flow measurement applied with time⁃difference method,an ultra⁃sonic flow measurement system applied with time⁃difference based on 16⁃bit MSP430F147 SCM of ultra⁃low power consumption is studied. The fundamental principle of this measurement is introduced,and then the hardware structure of the measurement system is discussed emphatically,finally the software design of this system is introduced in brief. The practical results show that the flow measurement system has the advantages of low power consumption,complete functions and strong reliability.

关键词

MSP430F147单片机/时差法/超声波流量测量/TDC-GP21

Key words

MSP430F147 SCM/time-difference method/ultrasonic flow measurement/TDC-GP21