| 注册
首页|期刊导航|中国组织工程研究|三维有限元分析钢板内固定治疗跟骨骨折*

三维有限元分析钢板内固定治疗跟骨骨折*

黄诸侯 李俊 杜景文 陈日齐 张建新

中国组织工程研究Issue(17):3094-3100,7.
中国组织工程研究Issue(17):3094-3100,7.DOI:10.3969/j.issn.2095-4344.2013.17.008

三维有限元分析钢板内固定治疗跟骨骨折*

Three-dimensional finite element analysis of calcaneus fracture treated with plate fixation

黄诸侯 1李俊 2杜景文 3陈日齐 4张建新5

作者信息

  • 1. 晋江市安海医院骨科,福建省晋江市 362200
  • 2. 苏州大学附属第一医院骨科,江苏省苏州市 215006
  • 3. 三门峡市中医院骨科,河南省三门峡市 472000
  • 4. 福州大学光弹实验室,福建省福州市 350003
  • 5. 厦门市中医院骨科,福建省厦门市 361009
  • 折叠

摘要

Abstract

BACKGROUND:There are many types of plate can be used for the treatment of calcaneus fracture, but it is not clear which type has the best effect. <br> OBJECTIVE:To observe and compare the biomechanical properties, such as stress, strain and displacement of three types of plate through loading them on the three-dimensional finite element model of calcaneus fracture. <br> METHODS:The three-dimensional finite element model of calcaneus fracture was established when the ankle joint was in neutral position and back stretches 20° position, then the type Ⅰ, type Ⅱ and type Ⅲ plates were used to fix the fracture model. Through loading force on the model, the stress distribution of plates and calcaneus, and displacement between fracture gaps were calculated. <br> RESULTS AND CONCLUSION:In the position of the neutral and back stretches 20°, the stress distribution of type Ⅰ, type Ⅱ and type Ⅲ plates was not uniform, and the stress at the front was higher than that at back. Comparatively, the stress distribution of type Ⅰ plate was more uniform than type Ⅱ plate and type Ⅲ plate. And the stress distribution of calcaneus at the front was higher than that at back, while the largest stress of the normal calcaneus was distributed on the tubercle. The maximum stress of calcaneus after fixed with type Ⅰplate was lower than that fixed with type Ⅱ and type Ⅲ plates. Displacement among fracture gaps occurred after fixed with three types of plates in two positions, and the displacement tendency was uniform. The results show that when compared with type Ⅱ and type Ⅲ plates, the stress of calcaneus after fixed with type Ⅰplate is smal er and more uniform which corresponds with the biomechanics principle.

关键词

骨关节植入物/数字化骨科/骨科三维有限元/跟骨骨折/钢板内固定/三维有限元/生物力学/其他基金

Key words

bone and joint implants/digital orthopedics/orthopedic three-dimensional finite element/calcaneus fracture/plate internal fixation/three-dimensional finite element/biomechanics/other grants-supported paper

分类

医药卫生

引用本文复制引用

黄诸侯,李俊,杜景文,陈日齐,张建新..三维有限元分析钢板内固定治疗跟骨骨折*[J].中国组织工程研究,2013,(17):3094-3100,7.

基金项目

福建省泉州市科技局资助项目(2007z52)。 (2007z52)

中国组织工程研究

OACSCDCSTPCD

2095-4344

访问量0
|
下载量0
段落导航相关论文