髋臼几何参数的CT测量

胡荣慧 贺斌 刘力 严睿 刘嘉凯 黄小波 张剑 丁薇

中国组织工程研究Issue(26):4841-4848,8.
中国组织工程研究Issue(26):4841-4848,8.DOI:10.3969/j.issn.2095-4344.2013.26.013

髋臼几何参数的CT测量

CT measurement of acetabulum geometric parameter

胡荣慧 1贺斌 1刘力 1严睿 1刘嘉凯 1黄小波 1张剑 1丁薇1

作者信息

  • 1. 昆明总医院医学影像科,云南省昆明市 650032
  • 折叠

摘要

Abstract

  BACKGROUND: Although, the previous studies on acetabular morphological characteristics have yielded some results, quantitative description of the acetabular surface morphology has not yet been unified because of the special nature of acetabular structure and location, and this is bound to affect the accuracy of the diagnosis and treatment of hip disease. OBJECTIVE: To investigate the CT measuring methods to acetabulum geometric parameters. METHODS: Seventy cases performed CT scan were selected, including 50 normal adults (a total of 100 hips on both sides) and 20 cases with unilateral congenital hip dislocation. The hip CT images of the subjects were treated with coronal reconstruction and three-dimensional reconstruction, in order to compare the coronal and three-dimensional measurement value of acetabulum upper chamber, and to compare acetabulum upper camber between the normal side and the abnormal side in the congenital hip dislocation group. The acetabulum posterior abduction angle, anterior acetabulum index and posterior acetabular index were measured in the images in accordance with scan bed and the body coronal plane. RESULTS AND CONCLUSION: The acetabulum upper camber measured in coronal plane and three-dimensional image was (39.99±6.1)° and (40.13±5.80)° respectively, and there was no significant difference (P > 0.05). The acetabulum upper camber measured value of the unilateral congenital hip dislocation patients in normal side and abnormal side on coronal plane was (48.95±3.80)° and (63.56±6.35)°, and there were significant differences (P < 0.01). There were significant differences in acetabulum posterior abduction angle, anterior acetabulum index and posterior acetabular index measured in both sides on the images in accordance with scan bed and the body coronal plane (P < 0.01), and there were no significant differences in accordance with coronal plane (P > 0.05). The measurement is more reliable on the images in accordance with the body coronal plane when measuring acetabulum posterior abduction angle, anterior acetabulum index and posterior acetabular index. It can reflect the acetabular real condition and provide quantitative indicators for the diagnosis and treatment of hip disease.

关键词

骨关节植入物/骨与关节图像与影像/髋臼/几何参数/髋关节/三维重建/外倾角/髋臼外展角/髋臼指数

Key words

bone and joint implants/photographs and images of bone and joint/acetabulum/geometric parameter/hip joint/three-dimensional reconstruction/camber angle/abduction angle/acetabulum index

引用本文复制引用

胡荣慧,贺斌,刘力,严睿,刘嘉凯,黄小波,张剑,丁薇..髋臼几何参数的CT测量[J].中国组织工程研究,2013,(26):4841-4848,8.

中国组织工程研究

OACSCDCSTPCD

2095-4344

访问量0
|
下载量0
段落导航相关论文