骨水泥加固椎弓根螺钉的生物力学特性

隆海滨 孙桂森 王卫国

中国组织工程研究Issue(39):6309-6314,6.
中国组织工程研究Issue(39):6309-6314,6.DOI:10.3969/j.issn.2095-4344.2015.39.014

骨水泥加固椎弓根螺钉的生物力学特性

Biomechanical properties of bone cement injectable canulated pedicle screw

隆海滨 1孙桂森 1王卫国2

作者信息

  • 1. 胜利油田中心医院脊柱外科,山东省东营市 257034
  • 2. 中南大学湘雅三医院骨科,湖南省长沙市 410015
  • 折叠

摘要

Abstract

BACKGROUND:Bony and structural feature often cause pulout strength decrease of pedicle screw, which induces loosening and pulout, and finaly results in fixation failure. Thus, it is very important to elevate the stability of pedicle screw. <br> OBJECTIVE:To detect the biomechanical stability of bone cement injectable canulated pedicle screw, and to provide reference for bone cement dosage. <br> METHODS: We selected T11-L4 samples of seven fresh adult corpses, containing 40 vertebral bodies. They were randomly divided into bone cement injectable canulated pedicle screw group and DTPSTM pedicle screw group (n=20). After screw implantation, 1, 2, 3 and 5 mL bone cement was injected. The diffuse distribution of bone cement was observed by imaging. The maximum axial pulout strength was measured. <br> RESULTS AND CONCLUSION:When the dose of bone cement was 1-3 mL, the average maximum axial pulout strength was significantly greater in the bone cement injectable canulated pedicle screw group than in the DTPSTM pedicle screw group (P < 0.05). When the bone cement dosage was 5 mL, no significant difference in the maximum axial pulout strength was detected between the two groups (P > 0.05). The regression equation was Y=25.269X+133.681 (R2=0.837) in the bone cement injectable canulated pedicle screw, and&nbsp;Y=32.039X+99.251 (R2=0.936) in the DTPSTM pedicle screw group. When the dosage of bone cement was 1-5 mL, the maximum axial pulout strength was highly positively correlated with bone cement dosage (|R| > 0.8). These results suggested that bone cement augmentation pedicle screw could apparently elevate the stability of the screw. The maximum axial pulout strength of the pedicle screw was positively correlated with bone cement dosage. After reaching the satisfactory fixation effects, the bone cement injectable canulated pedicle screw can reduce bone cement dosage, diminish the risk of bone cement leakage, and have more advantages than DTPSTM pedicle screw.

关键词

骨科植入物/脊柱植入物/骨水泥/椎弓根螺钉/生物力学/弥散分布/拔出力/把持力/三维重建

Key words

Bone Nails/Bone Remodeling/Biomechanics/Bioprosthesis

分类

医药卫生

引用本文复制引用

隆海滨,孙桂森,王卫国..骨水泥加固椎弓根螺钉的生物力学特性[J].中国组织工程研究,2015,(39):6309-6314,6.

中国组织工程研究

OA北大核心CSTPCD

2095-4344

访问量0
|
下载量0
段落导航相关论文