| 注册
首页|期刊导航|中国组织工程研究|钛板与丝线悬吊固定在颈椎后路单开门椎管扩大成形中应用的Meta分析

钛板与丝线悬吊固定在颈椎后路单开门椎管扩大成形中应用的Meta分析

阮文枫 金祺 刘辉 王文达 李景峰 冯帆 平安松

中国组织工程研究Issue(39):6390-6396,7.
中国组织工程研究Issue(39):6390-6396,7.DOI:10.3969/j.issn.2095-4344.2015.39.028

钛板与丝线悬吊固定在颈椎后路单开门椎管扩大成形中应用的Meta分析

Micro-titanium plate fixationversus suture suspension fixation in cervical posterior expansive open-door laminoplasty:a meta-analysis

阮文枫 1金祺 1刘辉 1王文达 1李景峰 1冯帆 1平安松1

作者信息

  • 1. 武汉大学中南医院,湖北省武汉市 430071
  • 折叠

摘要

Abstract

BACKGROUND:Many studies concern the comparison of micro-titanium plate fixation and suture suspension fixation during cervical posterior expansive open-door laminoplasty, but the sample size of many studies has limitations. There is lack of objective evaluation on advantages and disadvantages of micro-titanium plate. <br> OBJECTIVE:To systemicaly evaluate the efficacy and safety of micro-titanium plate fixationversus suture suspension fixation in cervical posterior expansive open-door laminoplasty. <br> METHODS: English and Chinese randomized controled trials were searched by two reviewers. They retrieved&nbsp;the Cochrane Central Register of Controled Trials (CENTRAL), PubMed, EMbase, the ISI Web of Knowledge Database, CNKI, CMB, VIP and Wanfang database for randomized controled trials addressing micro-titanium plate fixationversus suture suspension fixation in cervical posterior expansive open-door laminoplasty published from database foundation to March 1, 2015. The references were also searched by hand. Meta-analyses were performed by using the Rev-Man 5.3 software, provided by the Cochrane Colaboration. <br> RESULTS AND CONCLUSION: A total of 9 studies involving 642 patients were included. The results of meta-analyses showed that: (1) safety: There were no significant differences between the two groups in operation time [SMD=-0.02, 95%CI (-0.57, 0.54),P=0.95 > 0.05], and intraoperative blood loss [SMD=0.07, 95%CI (-0.26, 0.40),P=0.69 > 0.05]. (2) Efficacy: compared with suture suspension fixation, Japanese Orthopaedic Association Scores were higher [SMD=0.26, 95%CI (0.10, 0.42),P=0.001 < 0.05], the angle of the opened laminae was bigger [SMD=0.25, 95%CI (0.02, 0.48),P=0.04 < 0.05], cervical curvature was better [SMD=0.46, 95%CI (0.27, 0.65),P < 0.000 01], and incidence of axial symptoms was lower [RR=0.40, 95%CI(0.29, 0.56),P< 0.000 01] after micro-titanium plate fixation. These findings suggest that during expansive open-door laminoplasty for treatment of cervical spondylosis, micro-titanium plate fixation and suture suspension fixation can obtain good clinical outcomes. However, Japanese Orthopaedic Association Scores were higher and the angle of the opened laminae was better in micro-titanium plate fixation than in suture suspension fixation. Micro-titanium plate fixation could effectively prevent loss of cervical curvature and reduce the incidence of axial symptoms. For the poor quality of the original studies and smal sample size, a prudent choice is suggested. More high-quality large-sample studies are needed for further verification.

关键词

骨科植入物/脊柱植入物/颈椎病/微型钛板固定/丝线悬吊固定/单开门/Meta分析

Key words

Cervical Vertebrae/Internal Fixators/Meta-Analysis/Evidence-Based Medicine

分类

医药卫生

引用本文复制引用

阮文枫,金祺,刘辉,王文达,李景峰,冯帆,平安松..钛板与丝线悬吊固定在颈椎后路单开门椎管扩大成形中应用的Meta分析[J].中国组织工程研究,2015,(39):6390-6396,7.

中国组织工程研究

OA北大核心CSTPCD

2095-4344

访问量0
|
下载量0
段落导航相关论文