中国医药科学Issue(11):136-137,2.
快速压力蒸汽灭菌器的灭菌效果监测与分析
Abstract analysis of the sterilizing effect of rapid pressuresteam sterilizer
杨俊华 1王玫 1舒江红1
作者信息
- 1. 广州医学院第二附属医院,广东广州510260
- 折叠
摘要
Abstract
Objective To investigate and evaluate the sterilizing effect of rapid pressuresteam sterilizer. Methods 200 pans microinstruments were divided into control and experiment group,100 for each.For control group,the microinstruments were exposed on the pan,the position of 3 M chemical indicator card was not fixed,the result of indicator card was observed by the operator himself after sterilization.For experiment group,the microinstruments were put into a dedicated box,and then put on the pan,the indicator card was fixed in the box,two persons check the indicator card after sterilization.Compare with the chemical and biological monitoring results of the two groups. Results In the control group,the indicator card changed asymmetrically for 5 times,and did not change for twice,and biological culture did not passed for twice. In the experiment group,no abnormal condition as above was found. Conclusion The rapid pressuresteam sterilizer must be operated according to the technical manual.The operators must reinforce the check-over regime,accomplish the chemical and biological monitoring,then assure the quality of sterilization articles and the safety of operation.关键词
快速压力蒸汽灭菌器/灭菌监测Key words
Rapid pressuresteam sterilizer/Sterilization monitoring分类
医药卫生引用本文复制引用
杨俊华,王玫,舒江红..快速压力蒸汽灭菌器的灭菌效果监测与分析[J].中国医药科学,2013,(11):136-137,2.