中华耳科学杂志Issue(2):212-215,4.DOI:10.3969/j.issn.1672-2922.2013.02.010
微创入路人工耳蜗植入术*
Cochlear implantation with minimal access
摘要
Abstract
Objective To described an approach of cochlear implantation with a smaller skin incision of 3-cm. Meth-ods A total of 197 patients received Combi 40+©, Pulsar© or Sonata© implants with a novel approach of a 3-cm-long skin in-cision. The skin incision length was measured after closure of the skin. The operative duration and postoperative complications was also recorded. Results The average skin incision lengths after closure of the skin were 3.0 ± 0.3 cm. The average operative duration was 103.4 ± 22.4 min. No complications of cochlear implantation occurred during an average of 26.5 months of post-operative follow-up. Conclusions The minimal access for cochlea implantation can reduce the surgical complication rate with-out increasing operative difficulty, and cochlear implantation with a minimal access is more acceptable to the patients and their family.关键词
微创入路/人工耳蜗植入术/并发症Key words
Minimal access/cochlear implantation/complication分类
医药卫生引用本文复制引用
宋跃帅,戴朴..微创入路人工耳蜗植入术*[J].中华耳科学杂志,2013,(2):212-215,4.基金项目
国家自然科学基金面上项目(31071099,81070792),国家自然科学基金重点基金(81230020),国家科技支撑计划课题(2012BAI09B02),卫生部行业基金(30872862)。 ()