Abstract

To eliminate air leakage rate of rotary GGH (gas gas heater), many coal-fired power plants have adopted tubular GGH. As tubular GGH is seldom used and the relevant control and operation experience is insufficient. The paper introduces structure of tubular GGH and the control modes for units startup, operation and shutdown as well as main control circuits. The operation result of tubular GGH shows that gas temperature at the gas cooler outlet can be maintained at about 92℃and the system is in sound operation.

关键词

超低排放/管式GGH/控制模式/运行

Key words

ultra-low emission/tubular GGH/control mode/operation