| 注册
首页|期刊导航|浙江医学|参考方法测定血清葡萄糖的测量不确定度评价

参考方法测定血清葡萄糖的测量不确定度评价

谢服役 孙琦 吴巧萍

浙江医学Issue(3):188-191,226,5.
浙江医学Issue(3):188-191,226,5.

参考方法测定血清葡萄糖的测量不确定度评价

谢服役 1孙琦 1吴巧萍1

作者信息

  • 1. 315041 宁波市医疗中心李惠利医院检验科
  • 折叠

摘要

Abstract

Objective To explore the method and procedure for evaluation of measurement uncertainty of serum glucose in reference laboratory. Methods The concentration of glucose in serum samples was measured by the reference method which was recommended by the U. S. Centers for Disease Control and Prevention (CDC), and the sources of each uncertainty compo-nent in whole procedure of analysis were identified. The evaluation of uncertainty components was processed by using two types of method, then a combined standard uncertainty was calculated;final y, an expanded uncertainty was given according to 95%confidence interval. Results The average concentration of glucose was 15.20 mmol/L, the related combined standard uncer-tainty was 0.14 mmol/L and the expanded uncertainty(U) was 0.29 mmol/L (the desired level of confidence of approximately 95%, the coverage factor k=2). Conclusion Compared to the traditional measurement errors, the measurement uncertainty in refer-ence laboratory may reflect the measurement ability better, and which would be helpful for evaluation of measurement uncertainty in reference laboratory.

关键词

参考方法/血清葡萄糖/测量不确定度/标准不确定度和扩展不确定度

Key words

Reference method/Serum glucose/Measurement uncertainty/Standard and expanded uncertainties

引用本文复制引用

谢服役,孙琦,吴巧萍..参考方法测定血清葡萄糖的测量不确定度评价[J].浙江医学,2013,(3):188-191,226,5.