Through the analysis of unusual influent circumstances in a modified A/ A/ O sewage treatment plant of Guangzhou,some effective countermeasures were taken to deal with the high concentration of COD、SS、TP and high content of inorganic in SS. By controlling blower aeration to remain aerobic DO at 1. 8 mg / L to ensure the efficient nitrification,increasing the amount of sludge to remove SS ,regulating sludge recycle ratio to maintain a reasonable sludge concentration and organic content,setting up a effluent warning concentration of total phosphorus by 0. 7 mg / L to keep total phosphorus under 1. 0 mg / L with biological and chemical treatment,the effluent quality can eventually conform the primary B standard in《Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant》(GB 18918—2002)and designed standard.